keyence

v_kv_pro_ch03_5.pdf

page 14 mentions changing counter to 24 bit with memsw instruction for kv high speed count for encoder input set to 5 VDC with switch on side

count numbers

from test done with KV16DR and freq drive 2-24-11 1010 counts per rev of motor test of gearbox gave 50939

51532 50881 50554

1024*50 Ans = 51200 Ans/4 Ans = 12800 51200/2 Ans = 25600 50*1010 Ans = 5050

Memory Locations

dm200major counts
dm201counts desired

Utility Relays

KV_Programming_96M0366_UM_AS_5.pdf

section 1.3.8 utility relays

section 1.3.10 data memories

2002always ON
2003always off
2008on for first scan
2009turns on when result of arithmetic is negative or overflow (<)
2010turns on when result of arithmetic is zero (=)
2011turns on when result of arithmetic is positive (>)
2012turns on when result of arithmetic generates error

basic_course_24.pdf

hmi

wants password when uploading program to computer password is stored in application on computer (not HMI)